City of Providence, RI · pop. 190K
Thu19Nov3:00 PM
Building Board of Review
Thu Nov 19, 3:00 PM · 3 days ago
This agenda in plain words
Leer en españolThis is a meeting of the Building Board of Review in Providence, Rhode Island, on Thursday, November 19, 2026, at 3:00 PM at 780 Allens Ave, with a Zoom option. The board will first approve minutes from October 15, 2026, then hear four new requests from property owners who want to change houses or buildings for more families and need relief from certain building code rules.
- A request to change a two-family house into a three-family house. The owner asks for relief from several building code rules, including sprinklers, stair and ceiling heights, and fire protection of openings. Touches: Property at 430 Morris Ave, Plat 6, Lot 387, in an R-3 Residential District. Applicant and owner: Weiping Ren.. p. 1
- A request to change a two-family house into a three-family house. The applicant asks for relief from sprinkler, stair riser and tread, and exit door rules. Touches: Property at 768 Manton Ave, Plat 34, Lot 419, in an R-3 Residential District. Applicant: Chosen Generation, LLC. Owner: . p. 1
- A request to change an eight-unit apartment building into a four-unit building, with interior and exterior work and adding a story. The applicant asks for relief from several stair, elevator, story-count, and exit rules, and from a grab bar and shower seal rule. Touches: Property at 97 Angell Street, Plat 12, Lot 493, in an I-2 Institutional and Historic Overlay District. Applicant: Peter . p. 1
- A request to change a two-family house into a three-family house. The owner asks for relief from sprinkler, handrail height, stair opening, and exit door rules. Touches: Property at 53 Standish Ave, Plat 116, Lot 683, in an R-1 Residential District. Applicant and owner: Eddy Gonzalez.. p. 1
Words on this agenda, explained
- Relief
- Permission to not follow a specific building code rule that would otherwise apply.
- Applicant
- The person or company asking the board for a decision.
- Owner
- The person or company that owns the property.
- R-3 Residential District
- A zone of the city where homes are the main use, with rules about what can be built.
- Group R occupancies
- The building code's label for buildings where people live, such as houses and apartments.
- Minutes
- The written record of what was said and decided at an earlier meeting.
Written by AI from the agenda, Nov 14. Each point links to its page: read it there before you rely on it. Nothing here says how the board will vote.
6 items on this agenda match the land-use topicsSubdivisions (6)
Agenda items (6)Show only the 6 matching
- 1. WEIPING REN (Applicant/Owner): 430 Morris Ave, Plat 6, Lot 387, in an R-3 Residential District. As associated with a building permit application for interior alteration to change use from two-family dwelling to three-family dwelling, the applicant requests relief from the RI SBC-1 Sections: 3404.1- alterations; 420.4 and 903.2.8 – Automatic Sprinkler System required for Group R occupancies; 1011.5.2 – riser height and tread depth; and 1023.4 – interior exit stairway, openings; 716.2.2.3 – doors in interior exit stairway and ramps and exit passageway; 1207.2 – minimum ceiling heights; 420.3… p. 1
- 2. CHOSEN GENERATION, LLC (Applicant) and GRACE NASSANGA (Owners): 768 Manton Ave, Plat 34, Lot 419, in an R-3 Residential District. As associated with a building permit application for interior alteration to change use from two-family dwelling to three-family dwelling, the applicant requests relief from the RI SBC-1 Sections: 3404.1- alterations; 420.4 and 903.2.8 – Automatic Sprinkler System required for Group R occupancies; 1011.5.2 – riser height and tread depth; and Table 1006.2.1 – spaces with one exist or exit access doorway. p. 1
- 3. PETER CASALE/CASALE CODE CONSULTING, LLC (Applicant) and LOFTY AMBITIONS, LLC /JILL SUTTON(Owner): 97 Angell Street, Plat 12, Lot 493 in an I-2 Institutional and Historic Overlay District. As associated with a building permit application for interior and exterior alterations, including the addition of a story, and to change use from multi-family (8 dwelling units) to multi-family (4 dwelling units), the applicant requests relief from the RI SBC-1 Sections: 1023.2 – interior exit stairway-construction; 3002.7 – elevators, common enclosure with stairway; and, Tables 504.4 - allowable number o… p. 1
- 4. EDDY GONZALEZ (Applicant/Owner): 53 Standish Ave, Plat 116, Lot 683, in an R-1 Residential District. As associated with a building permit application for interior alteration to change use from two-family dwelling to three-family dwelling, the applicant requests relief from the RI SBC-1 Sections: 3404.1- alterations; 420.4 and 903.2.8 – Automatic Sprinkler System required for Group R occupancies; 1014.2 – handrails, height; 1023.4 – interior exist stairway – openings; and Table 1006.2.1 – spaces with one exit or exit access doorway. Documents for new matters can be accessed at: http://www.pr… p. 1
- 1. WEIPING REN (Solicitante/Propietario): 430 Morris Ave, Plat 6, Lote 387, en un Distrito Residencial R-3. Como asociado con una solicitud de permiso de construcción para alteración interior para cambiar el uso de vivienda de dos familias a vivienda de tres familias, el solicitante solicita exención de las Secciones RI SBC-1: 3404.1 - alteraciones; 420.4 y 903.2.8 - Sistema de rociadores automáticos requerido para ocupaciones del Grupo R; 1011.5.2 - altura de contrahuella y profundidad de peldaño; y 1023.4 - escalera de salida interior, aberturas; 716.2.2.3 - puertas en escalera de salida int… p. 2
- 3. PETER CASALE/CASALE CODE CONSULTING, LLC (Solicitante) y LOFTY AMBITIONS, LLC/JILL SUTTON (Propietario): 97 Angell Street, Plat 12, Lote 493 en un Distrito de Superposición Institucional e Histórica I-2. Como asociado con una solicitud de permiso de construcción para alteraciones interiores y exteriores, incluyendo la adición de un piso, y para cambiar el uso de multifamiliar (8 unidades de vivienda) a multifamiliar (4 unidades de vivienda), el solicitante solicita una exención de las Secciones RI SBC-1: 1023.2 – construcción de escalera de salida interior; 3002.7 – ascensores, recinto comú… p. 2