Town of Atkinson, NH · pop. 7K
Wed2Dec
Public Notices
Wed Dec 2 · in 10 days
Public Hearing - Planning Board
Agendatown-atkinsonnh.com
Minutesafter the meeting
Meeting page ↗town-atkinsonnh.comAdd to calendar.ics for Outlook, Google, AppleThis agenda in plain words
Leer en españolThis is a public hearing of the Atkinson Planning Board on proposed changes to the town's zoning rules, set for Wednesday, December 2, 2026 at 7 pm. The main items are allowing apartments in commercial zones, allowing family day care homes by right, removing a rule about reducing frontage requirements, and adding a "Contractor's Shop" use.
- A request to allow buildings with 3 or more apartments (multifamily use) without a special permit in commercial zones, where state law now requires it, if adequate infrastructure exists. Changes Sections 510 and 530. Touches: Owners and businesses in commercial zones (C, C-I, C-P, TC, and others listed in Section 510).The public may speak p. 1
- Changes to the rules for daycares: family day care homes and family group day care homes would be allowed by right if they follow state rules and have the needed building and occupancy permits. Changes Definitions Section 300, home occupation Section 450:3, and Sections 510 and 520. Touches: Families and people who run or plan to run a home daycare.The public may speak p. 6
- Removing Section 490, which let the Board of Adjustment reduce frontage requirements by up to 33 and 1/3%. Relief would instead go through a variance application to the ZBA. The minimum frontage requirements in Section 530 are not changing. Touches: Property owners who need reduced lot frontage.The public may speak p. 9
- Adding a "Contractor's Shop" as a defined use, meaning an enclosed space for machinery, services, building-product fabrication and interior storage. It would be allowed only in the C-I zone, with site plan approval. Touches: Contractors and businesses in the C-I zone.The public may speak p. 9
- Updating the agency name in Section 700:2 on converting a seasonal home to a year-round home. The change would require a special exception from the Board of Adjustment and written consent from the state environmental agency. Touches: Owners of seasonal or camp homes who want to live in them year-round.The public may speak p. 9
Words on this agenda, explained
- By right
- Allowed without needing a special permit or a vote from a board, as long as the rules are met.
- Multifamily
- A building with three or more separate homes or apartments.
- Frontage
- The width of a lot where it meets the street.
- Variance
- Permission from the Zoning Board of Adjustment to not follow a zoning rule, given when the set criteria are met.
- Special exception
- Permission from the Board of Adjustment for a use the zoning rules allow only under set conditions.
- Site plan approval
- Review and approval of how a property will be laid out, such as parking, drainage and buildings, before work begins.
Written by AI from the agenda, Nov 21. Each point links to its page: read it there before you rely on it. Nothing here says how the board will vote.
4 items on this agenda match the land-use topicsSite plans (3), Data centers & plants (1), Variances (1)
Agenda items (5)Show all 5
- …Y[3,4] N ee Deleted 1993 RR3 RR 2 TR2 TC C-I C C-P RR2/SC R ff Research and development facilities that meet Performance Standards in Section 685 of Site Plan Review Regulations N N N N Y[4] N Y[3,4] N gg Self-Service Storage Facility (4/97) N N N N Y[4] Y[3,4] N N hh Refuse and garbage (not town generated) incineration, storage or disposal (1999) N N N N N N N N ii Junk yards; asphalt plants, meat rendering plants; sand, gravel, cement or stone processing plants; piggeries; oil refining (1999) N N N N N N N N jj Wrecking and salvage yards; auto dismantling (1999) N N N N N N N N kk Manufactu… p. 2
- …ft, whichever is less 2 stories or 35 feet, whichever is less 3 stories or 35 feet, whichever is less --35 feet 35/55 feet [9] h General regulations Site Plan approval Multi-family Non-residential Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes p. 4
- …ved or persons outside the family are to be employed at the proposed location or if hazardous materials are to be stored there. In addition, a formal site plan review may be required if deemed necessary. SECTION 510 PERMITTED USES ZONES RR3 RR2 TR2 TC C-I C C-P RR2/ S CR aa Family Day Care Home and Group Family Day Care Y[6] Y[9] Y[6] Y[9] Y[6] Y[9] Y[6] Y[9] Y[6] Y[9] Y[6] Y[9] N Y[9] N Y[9] Foot Notes 9 - Family Child Day Cares and Group Family Day Cares are allowed on lots where residential uses are permitted and do not require site plan approval, if the program meets the requirements of th… p. 7
- …hat the procedure lacks clarification on process or criteria. Relief from the frontage requirements within Atkinson is able to be completed through a variance application with the ZBA with well outlined procedures and criteria. Minimum frontage requirements, as stated in Section 530 are not being changed. SECTION 490 REDUCTION OF FRONTAGE REQUIREMENTS 490:1 The Board of Adjustment may reduce frontage requirements by no more than 33 and 1/3% where street layouts and lot shapes may lend greater usage of the property under consideration, provided, however, that at the building line, a distance of… p. 9
2 more passages from inside the staff reports, forms and minutes attached to this agenda are not listed as agenda items. Search finds every word of them.