Marion County, FL · pop. 386K
Mon12Oct9:00 AM
Development Review Committee
Mon Oct 12, 9:00 AM · Office of the County Engineer · Final · 41 days ago
Agendamarionfl.legistar1.comAttachment5.3 Whisper Woods - Final Plat 33542.pdfAttachment5.4 Calesa Market District - Major Site Plan 000Attachment5.5 Sabana Farms Amenity - Major Site Plan 00112Attachment5.6 Calesa Township - The Nest (Rev to 30410) - Attachment5.7 Fawn Lake Estates Pre-Plat 001036.pdfAttachment6.3 Grand View Church - Waiver Request to Major Attachment6.4 Grand View Church - Waiver Request to BufferAttachment6.5 Hyatt Family Division - Family Division Waiv
Minutesnot posted yet
Meeting page ↗marionfl.legistar.com8 items on this agenda match the land-use topicsSite plans (5), Subdivisions (3), Special use (1)
Agenda items (24)Show only the 8 matching
- Members of the Public Are Advised That This Meeting / Hearing Is a Public Proceeding, and the Clerk to the Board Is Making an Audio Recording of the Proceedings, and All Statements Made During the Proceedings, Which Recording Will Be a Public Record, Subject to Disclosure Under the Public Records Law of Florida. Be Aware, However, That the Audio Recording May Not Satisfy the Requirement for a Verbatim Transcript of the Proceedings, Described in the Notice of This Meeting, in the Event You Desire to Appeal Any Decision Adopted in This Proceeding. If an Applicant Wishes to Appeal an Item, a Request Must Be Sent to Developmentreview@marionfl.org in a Timely Manner. p. 1
- 1.ROLL CALL
- 2.PLEDGE OF ALLEGIANCE p. 1
- 3.Adopt the Following Minutes: p. 1
- 3.1.October 5, 2026
- 4.PUBLIC COMMENT
- 5.Consent Agenda: Staff Has Reviewed and Recommends Approval p. 1
- 5.1.Classic Acres Phase 1 - Agricultural Lot Split Parcel #: 12654-000-00 #32696 Rogers Engineering p. 1
- 5.2.Reddick Ranches - Agricultural Lot Split Parcel #: 05870-006-02 #AgLotSplit-001016-2026 Rogers Engineering p. 1
- 5.3.Whisper Woods - Final Plat Parcel #: 9007-0000-12 #33542 JCH Consulting Group p. 1
- 5.4.Calesa Market District - Major Site Plan Parcel #: 35300-000-45 #MajorSite-000632-2026 Kimley-Horn and Associates p. 1
- 5.5.Sabana Farms Amenity - Major Site Plan Parcel #: 13709-010005 #MajorSite-001128-2026 Tillman & Associates Engineering, LLC p. 1
- 5.6.Calesa Township - The Nest (Revision to AR30410) - Major Site Plan Parcel #: 3546-0016002 #MajorSite-000956-2026 Tillman & Associates Engineering, LLC p. 1
- 5.7.Fawn Lake Estates - Preliminary Plat Parcel #: 39169-000-00 #PrelimPlat-001036-2026 Tillman & Associates Engineering, LLC p. 2
- 6.SCHEDULED ITEMS:
- 6.1.SW Hwy 484 Center - Waiver Request to Parking Area Landscaping Parcel #: 41200-056-03, 41200-056-15, 41200-056-16 #WaiverSTA-001332-2026 Kimley-Horn and Associates LDC 6.8.7.A Parking areas and vehicular use areas CODE states A minimum five-foot wide landscape area consisting of shrubs and groundcovers, excluding turfgrass, shall be provided around the perimeter of parking areas to form a landscape screen with a minimum height of three feet achieved within one year of planting. A land use buffer that abuts a parking area may satisfy this requirement. APPLICANT - Per discussions with County staff, this waiver request is for the deferral of the installation of the code required five-foot-wide landscape area/screen around the perimeter of the parking areas adjacent to the outparcels due to the unknown future site layouts of the outparcel developments. The requested deferral period is 36… p. 2
- 6.2.Fawn Lake Estates - Improvement Plan - 001215 - Waiver Request to Improvement Plan in Review Parcel #: 9027-0000-02 #WaiverPIR-001428-2026 Tillman & Associates Engineering, LLC LDC 6.13.6.A(3)(c) Stormwater quality criteria CODE states Dry retention systems that have a depth of six feet or less, measured from top of bank to pond bottom, with side slopes that are no steeper than 4:1 and sodded bottoms; APPLICANT requests a waiver for 7' pond depths. The proposed ponds are 7' deep with 4:1 sodded side slopes and bottoms. The additional 1' of pond depth is not a significant departure from code criteria, which limits pond depths to 6'. DRA’s 1, 2 and 3 are dry retention ponds with overflow elevations at 5.0 ’depth in DRA’s 1 and 2 and overflow depth of 4.0’ in DRA 3. DRA's 1 & 2 have a total depth of 7.0' and DRA 3 is 6.0' deep. DRA’s 1A, 2A and 3A are wet detention ponds with a total depth … p. 3
- 6.3.Grand View Church - Waiver Request to Major Site Plan Parcel #: 35300-163-00 #WaiverSTA-001360-2026 Radcliffe Engineering LDC 2.21.1.A(1) - Major Site Plan CODE states a Major Site Plan shall be submitted for review and approval prior to the issuance of a Building Permit or prior to the construction of site improvements when proposed improvements exceed any of the following thresholds (select all that are applicable): (1) Collectively, all existing and proposed impervious ground coverage equals or exceeds 35 percent of the gross site area or 9,000 square feet. APPLICANT requests waiver of Major Site Plan to add a 1,117 square foot classroom to the existing 10,908 square foot church building on the 11-acre site. Existing facilities were constructed per Site and Drainage Plan previously approved in 1996. Stormwater Control Plan to be provided for improvements exceeding allowable… p. 4
- 6.4.…APPLICANT - Existing Church has SUP #951005SU, dated October 17, 1995. Stating: The trees within the required side setbacks be maintained to act as a buffer between the subject site and adjacent properties. Existing trees were utilized in original Site Plan Approval October 29, 1996. Applicant requests to use current buffering. LDC 6.8.6.K(3) Buffers CODE states C-Type buffer shall consist of a 15-foot-wide landscape strip without a buffer wall. The buffer shall contain at least two shade trees and three accent/ornamental trees for every 100 lineal feet or fractional part thereof. Shrubs and groundcovers, excluding turfgrass, shall comprise at least 50 percent of the required buffer and form a layered landscape screen with a minimum height of three feet achieved within one year. Table 6.8.2 Requires Type C Buffer adjacent to R.O.W. APPLICANT - Existing Church has SUP #951005SU, dated… p. 5
- 6.5.…LDC 2.16.1.B(10) - Family Division CODE states a parcel of record as of January 1, 1992 that is not located in a recognized subdivision or an Ag Lot Split. and is located in the Rural Lands may be subdivided for use of immediate family members for their primary residences. Within the Farmland Preservation Area, each of the new tract and the remaining parent tract must be at least three (3) acres in size. Within the Rural Lands. outside of the Farmland Preservation Area each of the new tract and the remaining parent tract must be at least one (1) acre in size. In the Urban Area, only parcels of record as of January 1, 1992 which are Low Residential property exceeding two (2) acres in size may be divided for the use of immediate family members for their primary residences up to the maximum density of one (1) dwelling unit per gross acre. Immediate family is defined as grandparent, parent, … p. 6
- 7.Conceptual Review Items: p. 6
- 8.DISCUSSION ITEMS:
- 9.OTHER ITEMS:
- 10.ADJOURN: