City of Friendswood, TX · pop. 41K
Mon3Aug5:30 PM
City Council
Mon Aug 3, 5:30 PM · Council Chambers, City Hall,, 910 South Friendswood Dr., Friendswood · 4 months ago
Agendafriendswoodtx.api.civicclerk.comMinutesfriendswoodtx.api.civicclerk.comMeeting page ↗friendswoodtx.portal.civicclerk.com
3 items on this agenda match the land-use topicsInfrastructure (2), Water & sewer (1)
Agenda items (43)Show all 43
- A.…flow monitoring, assessment of existing infrastructure, evaluation of inflow and infiltration (I&I), lift station optimization, and preparation of a long-term Capital Improvement Plan (CIP). The updated wastewater flow monitoring represents the first city-wide monitoring effort since the 2016 Sanitary Sewer Evaluation Study and provides valuable information to measure the impact of previous I&I reduction projects while identifying additional opportunities for system improvements. This presentation has been scheduled to provide City Council with an overview of the completed Wastewater Master Plan, including the study methodology, key findings, recommended capital improvement projects, system capacity evaluation, and implementation strategy. Freese and Nichols, Inc. will present the study results and answer questions about future planning recommendations and project implementation. p. 2
- B.…improvements needed to support future growth, improve system reliability, and maintain regulatory compliance. The study included the development of an updated city-wide hydraulic model, wastewater flow monitoring, assessment of existing infrastructure, evaluation of inflow and infiltration (I&I), lift station optimization, and preparation of a long-term Capital Improvement Plan (CIP). The updated wastewater flow monitoring represents the first city-wide monitoring effort since the 2016 Sanitary Sewer Evaluation Study and provides valuable information to measure the impact of previous I&I reduction projects while identifying additional opportunities for system improvements. This resolution adopts the completed Wastewater Master Plan, including the study methodology, key findings, recommended capital improvement projects, system capacity evaluation, and implementation strategy. p. 2
- L.…The City's adopted Water and Wastewater Impact Fee Capital Improvements Plan identifies the upsizing of Lift Station No. 27 as a necessary capital improvement to accommodate future wastewater demand. An engineering evaluation determined that the recommended improvements will increase the lift station's firm pumping capacity through the addition of a third pump, providing the capacity needed to support anticipated growth within the service area. The City solicited Competitive Sealed Proposals (CSP No. 2026-10) for construction of the project. Proposals were evaluated based on qualifications, experience, project approach, and cost. McDonald Municipal and Industrial demonstrated a strong understanding of the project's complexity and presented an approach focused on maintaining operations while minimizing construction-related risk. Based on the evaluation criteria established in the… p. 3